data sheet flow transmitter (flr) ultrasonic flowmeter < m-flow pw > flr, fls, fly this meter is a clamp-on type ultrasonic flowmeter for permanent use based on transit time measuring method. the m-flow pw is ideal for clean liquids containing no air bubbles such as pure water. the easy-to-use compact and lightweight design is intended for integration into mechani- cal devices. the flowmeter applicable to small and medium size pipes of diameter range from 25mm to 600mm pro - vides superior cost performance. features 1. ease of use: the detector (type: flse 2) is mountable quickly and easily. the parameters necessary for measurement can be configured on the surface of flow transmitters housing case by menu-driven software. 2. compact and light weight: the adoption of the latest electronics technology has re - duced the size and weight of the flow transmitter to one- fifth of our general use flow transmitter. 3. superior temperature effect: the adoption of sound velocity measurement system, which calculates sound velocity from transit time, keeps the flowmeter unaffected by the temperature and the pressure of the fluid to be measured. 4. quick response: with the use of fast-speed transit time processor, the system cycle is 0.2 sec that is applicable to short batch process. 5. multilingual: the following languages are supported for display: eng - lish, japanese, french, german and spanish 6. synchronization (option): simultaneous transmission to two or more converters is allowed. cross-talk between flowmeters located closely or acous - tic interference between flowmeters installed on the same pipe line can be removed by using this synchro - nization function of transmission timing of ultrasonic waves. specifications operational specifications system configuration: the system is composed of a detector (model fls) and a flow transmitter (model flr), real- izing single-path system. detector (flse12) (flse22) detector (flse41) application: clean liquids that pass ultrasound and do not contain air bubbles (such as pure water and chemical solution) turbidity: 10000deg (mg/l) or less fluid temperature (continuous use rating): -20 to +100degc (type: flse 2 3-y) 0 to +120degc (type: flse 2 3-a) -20 to +80degc (type: flse 1) with silicon rubber for acoustic couplant 0 to +60degc with silicon-free grease for acoustic couplant type of flow: well-developed turbulent or laminar flow in a full-filled pipe ( ) ( ) detector (flse31) date EDS6-123I apr. 1, 2011
2 flr, fls, fly performance specifications accuracy rating: plastic pipe internal diameter velocity: 2m/s or higher velocity: less than 2m/s ? 25 to ?50mm 2.5% of rating 0.05m/s ?50 to ?600mm 1.5% of rating 0.03m/s metal pipe internal diameter velocity: 2m/s or higher velocity: less than 2m/s ?50 to ?600mm 2% of rating 0.04m/s response time: system cycle: 0.2s dead time: 0.2s or less, time constant: 0.1s power consumption: 15va or less for ac power supply 5w or less for dc power supply permissible air volume rate: up to 0.2% at 1 m/s (inversely proportional to velocity) short-term thermal stability: 140deg.c, 30min (in case flse 2) note: use flse31/flse41 at the tempera - ture of 80c or lower. applicable flow pipe: v -20 to 80c z pipe material v flse12 flse22 flse31 flse41 note 1: select flse31 or flse41 if the pipe is made of pp or pvdf. the wall thickness of pp pipe is 15 mm or less, and that of pvdf pipe is 9 mm or less. note 2: select flse31 or flse41 for the pipes that do not transmit ultrasound easily such as those made of cast iron, lining pipes, and old steel pipes. note 3: when the 9th digit in the code symbol is a, the applicable piping diameter is 50 to 150mm. detector ?25 to ?100mm ?50 to ?225mm note 3 ?50 to ?300mm ?50 to ?100mm ?300 to ?600mm plastic (pvc, etc.) note 1 plastic (pvc, etc.) note 1 metal (stainless steel, steel, copper, aluminum, etc.) note 2 plastic (pvc, pp, pvdf, etc.) metal (stainless steel, steel, copper, aluminum, etc.) note 2 metal (stainless steel, steel, copper, aluminum, etc.) internal pipe diameter 9th digit in code symbol y...-20 to +100c a...0 to +120c installation method fluid temperature range liner: tar epoxy, mortar, rubber, and others fundamental straight pipe: 10d for upstream and 5d for down - stream (d: internal pipe diameter) refer to conditions on straight pipe for details. velocity: 0 to 0.3 ... 10m/s power supply: 100 to 120v ac 10%, 50/60hz or 200 to 240v ac 10%, 50/60hz or 20 to 30v dc signal cable: co-axial cable up to 30m and thermal stabil- ity of 100 deg.c environment: non-explosive environment without direct sunlight, corrosive gas and heat radiation ambient temperature: -20 to +50deg.c for flow transmitter -20 to +60deg.c for detector ambient humidity: 90%rh or less grounding: class d (100 or less) synchronization (option): simultaneous transmission eliminates cross talk between multiple flow meters and mu - tual acoustic interference. number of connectable units: up to 31 cable length: up to 15m master/slave selectable arrester (option): arrester unit for outputs available (while ar - rester for power supply incorporated as stan- dard) 3 configuration: fully configurable from the 4-key pad (esc, , , ent) on the surface of flow transmit - ters housing case by menu-driven software zero adjustment: set zero/clear available damping: 0 to 100s (every 1s) configurable for analog output and display low flow cut off : 0 to 5m/s configurable alarm: hardware fault/process fault applicable to digital output burnout: analog output : hold/over-scale/under-scale/ zero selectable total: hold/count selectable working timer: 0 to 100s (every 1s) configurable bi-directional range: forward and reverse ranges configurable in- dependently hysteresis: 0 to 10% of acting range configurable acting range applicable to digital output auto-2 ranges: forward 2 ranges configurable independently hysteresis: 0 to 10% of acting range configurable acting range applicable to digital output flow switch: lower and upper switching points configu - rable independently acting point applicable to digital output total switch: +total switching point configurable acting point applicable to digital output physical specifications enclosure protection: jetproof type (ip65) both for converter and detector (flse 2: when waterproof bnc connector is provided) flse 1: immersion-proof type (ip67) (when the terminal block is filled with silicon rubber after wiring) mounting: flow transmitter: wall or 2b pipe mount detector: clamped on pipe surface acoustic coupler: silicon rubber or silicon-free grease material: flow transmitter: plastic abs detector (type: flse 2): plastic pbt for sensor housing, sus304 for guide frame detector (type: flse 1): plastic pbt for sensor housing, sus304 for sensor cover, sus304 and pbt for guide rail sensor cable: 3d2v with outside diameter 5mm dimensions: flow transmitter: h140 x w137 x d68mm detector: h50 x w228 x d34mm (flse1) h50 x w348 xd34mm (flse2) h40 x w500 x d80mm (flse3: mounting v method) h40 x w72 x d60mm (flse4: mounting z method) mass: flow transmitter: 0.8kg detector: 0.3kg (flse1) / 0.4kg (flse2) 1kg (flse3: mounting v method) 0.4kg (flse4: mounting z method) functional specifications analog output: 4 to 20 ma dc (1 point) max. load resistance : 600 digital output: + total, - total, alarm, acting range, flow switch or total switch arbitrarily available transistor open collector: 1 point (do1) capacity: 30v dc, 0.1a normal off/on selectable total pulse: 1pulse/day to 100pps (pulse width: 5, 10, 50, 100 or 200ms) mechanical relay contact: 1point (do2), with socket (exchangeable) normal close/open selectable capacity: 220v ac /30v dc, 1a (resistive load) mechanical expected life: more than 2 x 10 5 operations (under rated load) total pulse: 1pulse/day to 1pps (pulse width: 50, 100 or 200ms) communication interface (option): rs-232c equivalent / rs-485 number of connectable units: one (rs-232c)/ up to 31 (rs-485) baud rate: 2400/4800/9600/19200 bps select - able parity: none/odd/even selectable stop bit: 1 or 2 bits selectable cable length: up to 15m (rs -232c)/up to 1km (rs-485) data: velocity, flow rate, forward total, re - verse total, status, etc. display device: 2-color led (normal: green, extraordinary: red) lcd with 2 lines of 16 characters and back light display language: english, japanese, french, german or span- ish selectable velocity/flow rate display: instantaneous velocity/flow rate display (the flow of opposite direction is displayed by mi- nus numerals.) numeral: 7 digits (decimal point be counted as 1 digit) unit: metric/inch system selectable metric system inch system velocity m/s ft/s flow rate l/s, l/min, l/h, kl/h, ml/d, m 3 /s, m 3 /min, m 3 /h, mm 3 /d, bbl/s, bbl/min, bbl/h, mbbl/d gal/s, gal/min, gal/h, kgal/h, mgal/d, ft 3 /s, ft 3 /min, ft 3 /h, mft 3 /d, bbl/s, bbl/min, bbl/h, mbbl/d note: the gal means usgal. total display: display of forward or reverse total numeral: 7digits (decimal point be counted as 1digit) unit: metric/inch system selectable metric system inch system total ml, l, m 3 , km 3 , mm 3 , mbbl, bbl, kbbl gal, kgal, ft 3 , kft 3 , mft 3 , mbbl, bbl, kbbl, acre-in, acre-ft 4 flr, fls, fly conditions on straight pipe l 10d detector in case that flow control valve exists on upstream side. in case that flow control valve exists on downstream side. l 30d 1.5d l 50d 0.5d or more 10d or more 10d or more d check valve p stop valve 10d or more 90 bend tee diffuser reducer various valve pump (note) the source : jemis-032 classification upstream side downstream side ( d : inside diameter of pipe) l 5d l 5d l 5d l 50d l 10d l 10d l 10d l 30d 5 code symbols 6 flr, fls, fly outline diagram (unit:mm) m-flow pw u bolt (m8) pipe mount (option) mtg. plate mtg. holes 2-?9 mtg.pipe jis 2b cable gland 140 170 (197) 70 137 130 69 2.5 for power supply and output cable (pg13.5) for sensor cable (pg9) external grounding terminal 7 connection diagram to flow transmitter + g chain view from p mounting spring frame guide 501 33 461 (10) sensor frame name plate spacing : 0 to 270 p 4102 400 5 5 47 flr, fls, fly |
Price & Availability of EDS6-123I |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |